4
D. Prefabricated fireplace: Refer to the manufactures fireplace instruction manual for specific
information regarding the running of a gas line into that particular model. A typical installation
involves the insertion of a 1/2 inch gas pipe through the gas line tube provided by the man-
ufacturer from outside the fireplace. The Knockout on the inside of the fireplace is removed
as the gas pipe is punched through the fireplace. (See Figure 3).
E. Masonry fireplace: A 1/2 inch gas supply line must be provided to the firebox. Most install-
access hole through the masonry wall. The supply line should be
se
cured and sealed by mortar within the access hole. The supply line should also have a
.
shutoff valve either in the wall or inside the fireplace (see Figure 4).
GAS LOG INSTALLATION
(See Figure 1 Parts List as a guide to reference part numbers.)
BURNER PAN INSTALLATION
NOTE: Use pipe compound on all male threads to seal joints.
A.
Determine if the r
eplace has a right or left hand gas line feed.
The circular “Dimpled” hole covering must be knocked out on
the appropriate side (right or left) of the burner pan.
Brace panon w
orkbenc
h when removing burner
knock-out.
B.
Locate 3/8” locknut (Part #12) and washer (Part #21), and
attach them to the 3/8” brass ori
fice elbow (Part #11) Do
not fasten the locknut on the “
flared” end.
C.
Slide the 3/4” burner support spacer (Part # 10) over the
Dual Burner bar (Part #9) and move spacer to opposite
side of the gas inlet connection (See Figure 5).
D.
Secure the intake end of the Dual burner bar (Part # 9)
to the burner pan (Part # 8) through the knock-out hole
selected (right or left hand) with the 3/8” brass orifice
elbow (Part # 11),3/8” locknut (Part # 12), and washer
(Part #21) previously assembled in Step B (See Figure 6).
E.
Tighten elbow until
firmly attached to the Dual burner bar.
Then, firmly tighten the attached lock-nut on the elbow to
seal the burner bar to the wall of the burner pan.
Figure 3. Gas line installation - Prefabricated Fireplace
Figure 4. Gas line installation - Masonry Fireplace
Figure 5. Burner bar placement
Figure 6. Burner bar connection
ations require drilling an
NOTE:
Strike knock-out plug with a punch or drift.
MINIMUM FIREPLACE SIZE
Size
Depth Height Width
NG-BTU
18 12" 20" 20" 50,000
24 14" 24" 25" 60,000